Paper
15 June 1989 Factors Influencing The Depth Of Penetration Of He-Ne Laser In Whole Blood
S. C. Tjin, D. Kilpatrick
Author Affiliations +
Proceedings Volume 1067, Optical Fibers in Medicine IV; (1989) https://doi.org/10.1117/12.952107
Event: OE/LASE '89, 1989, Los Angeles, CA, United States
Abstract
The depth of penetration (DOP) of a helium-neon (He-Ne) laser (wavelength of 633nm) in whole blood had been widely speculated to range from 0.5mm to 1.5mm. However, due to technical difficulties in determining the DOP, one of which is the problem of detecting the forward scattered light in blood, these speculations had not been quantitatively verified. A knowledge of the DOP as a function of haematocrit and oxygen saturation level is important in the development of a dual-fibre laser Doppler velocimeter for in vitro flow measurements when it is desirable to project the laser beam as far away from the fibre tip as possible. Using two multimode optical fibres, we were able to set up a simple system to measure the DOP in whole blood. The two fibres, potted and polished, were aligned inside a tube filled with blood and with its ends sealed. One fibre admits light from a 15mW He-Ne laser into the blood and the other detects the forward scattered light. The DOP is defined as the separation between the two fibres such that the signal, due to diffusion of red blood cells, disappears in the noise spectrum. Two properties of blood were varied separately while keeping the other constant. Haematocrit (HCT) was varied by dilutions with sodium chloride (saline) solutions and blood oxygenation varied by bubbling air into the sample. The DOP was found to vary with haematocrit in an approximately exponential manner with penetration at HCT 40 of ≈ 1.9mm and at HCT 5 of ≈ 6mm. The DOP also varies with oxygen saturation with a typical range of 1.6mm for desaturated blood to 3mm for saturated blood. These distances will enable sufficient penetration of a two fibre system to allow measurement of blood velocity especially in the arterial circulation.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S. C. Tjin and D. Kilpatrick "Factors Influencing The Depth Of Penetration Of He-Ne Laser In Whole Blood", Proc. SPIE 1067, Optical Fibers in Medicine IV, (15 June 1989); https://doi.org/10.1117/12.952107
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood

Oxygen

Optical fibers

Doppler effect

Helium neon lasers

Light scattering

Velocity measurements

Back to Top