16 March 2020 Comprehensive quantitative evaluations of reconstruction method using oil-gel-based phantom in ultrasound computed tomography
Atsuro Suzuki, Yushi Tsubota, Wenjing Wu, Kazuhiro Yamanaka, Takahide Terada, Kenichi Kawabata
Author Affiliations +
Abstract
The performance of a reconstruction method in ultrasound computed tomography (CT) ideally should be evaluated using various kinds of phantoms at a wide range of speeds of sound when inclusions are made. However, generating real phantoms is more time consuming than generating simulated ones. In our previous study, we developed an oil-gel-based phantom by including water or salt water. In this study, we designed an evaluation method including various contrast conditions using the oil-gel-based phantom by changing the liquid and temperature. The phantom including water or salt water in 10-, 7-, 5-, or 3-mm holes was measured using our prototype ultrasound CT at temperatures of 15, 17.5, 20, 22.5, 25, 27.5, and 30°C, making the number of measurements 14. For these conditions, the difference (= contrast) in the speed of sound between the inclusions and the oil gel was −37 to 92 [m/s]. The filtered back projection (FBP) and full waveform inversion (FWI) were evaluated. The mean error of the speeds of sound in inclusions with the FBP and FWI were 17.1 ± 14.9 and 8.8 ± 10.1 [m/s], respectively. The mean percentage error of the sizes of the phantom (51 mm) and inclusions with the FBP and FWI were 22.5 ± 22.5% and 3.9 ± 4.3%, respectively. A single oil-gel-based phantom provided various contrast conditions after the temperature and liquid were changed. This kind of phantom can be used for comprehensive quantitative evaluations of the reconstruction method.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Atsuro Suzuki, Yushi Tsubota, Wenjing Wu, Kazuhiro Yamanaka, Takahide Terada, and Kenichi Kawabata "Comprehensive quantitative evaluations of reconstruction method using oil-gel-based phantom in ultrasound computed tomography", Proc. SPIE 11319, Medical Imaging 2020: Ultrasonic Imaging and Tomography, 113190L (16 March 2020); https://doi.org/10.1117/12.2548382
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultrasonography

Computed tomography

Water

Breast

Tissues

Liquids

Temperature metrology

Back to Top