1 December 1989 Use Of The Diamond Cell In An Industrial Laboratory
R. L. Barbour, J. D. Stephens, D. G. Cameron
Author Affiliations +
Proceedings Volume 1145, 7th Intl Conf on Fourier Transform Spectroscopy; (1989) https://doi.org/10.1117/12.969387
Event: Seventh International Conference on Fourier and Computerized Infrared Spectroscopy, 1989, Fairfax, VA, United States
Abstract
The traditional method for recording the IR spectra of solids has been KBr pellet transmission spectroscopy. This technique has several disadvantages: sample preparation time, matrix contamination, spectral distortion, ion exchange, a limited spectral range, scattering, loss of sample integrity during grinding, etc. In recent years, diffuse reflectance, ATR, photoacoustic reflectance, and external reflectance have been used increasingly, facilitated by the high SNR of FT instruments. In many cases, the diamond cell is an attractive alternative to all of these. The spectral range is -100 -1 to the UV, excluding the 2200-2000 cm -1 region. Spectral distortion, usually a great problem with inorganics, is greatly reduced as a result of sample homogeneity (from a spectral point of view) and refractive index matching. There is no matrix contamination: scattering, background slope, and all absorption bands are from the sample. There is no ion exchange. The sample size requirements are minimal. Finally, sample preparation requires the somewhat lost. but powerful, art of microscopic examination. In some instances, there may be sample orientation or pressure induced phase changes associated with the use of the diamond cell. A common misconception is that an IR microscope is needed to use the diamond cell. In fact, ~5 minutes will suffice without a beam condenser; 1 minute is all that is needed with one. In part, this is because one usually has excellent control of the optical thickness; with experience, the cell can easily be assembled to give bands in the 0.7-1.5 absorbance range, and making the sample thinner merely involves pressing the diamonds together. Given the above, the microscope should only be used for inhomogeneous samples as one loses all information below 700 cm-1, the region of greatest value when studying inorganics. We also note that the cell can readily be moved from a mid-IR to a far-IR bench. We have moved to the point where this is the dominant sampling technique, with ATR being the next most important. Diffuse reflectance and KBr pellets are seldom used. The cell has been used on inorganics (mid and far IR) including extremely small pure mineral samples selected by hand. It is also used for polymers, polymer inclusions, filter deposits, pure (and not so puce) organics, and general "what is this stuff" samples. Examples of a wide variety of analyses will be given.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. L. Barbour, J. D. Stephens, and D. G. Cameron "Use Of The Diamond Cell In An Industrial Laboratory", Proc. SPIE 1145, 7th Intl Conf on Fourier Transform Spectroscopy, (1 December 1989); https://doi.org/10.1117/12.969387
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diamond

Ion exchange

Reflectivity

Scattering

Contamination

Diffuse reflectance spectroscopy

Distortion

RELATED CONTENT

Pressure-tuning FT-Raman spectroscopy
Proceedings of SPIE (January 31 1994)
The Infrared Microscope A Versatile And Universal Sampling...
Proceedings of SPIE (December 01 1989)
Correction of tissue autofluorescence by reflectance spectrum
Proceedings of SPIE (September 12 2002)
Microsample Analysis Using An Infrared Microscope
Proceedings of SPIE (December 20 1985)

Back to Top