Presentation + Paper
13 December 2020 Radiation damage testing status of the CCDs for the SMILE SXI
Author Affiliations +
Abstract
The joint European Space Agency and Chinese Academy of Sciences Solar wind Magnetosphere Ionosphere Link Explorer mission (SMILE) aims to develop a global scale understanding of the interaction between the solar weather and the Earth’s magnetosphere-ionosphere. The soft X-ray imager (SXI) is one of the instruments on board and will observe photons emitted in the 200 eV to 2000 eV energy range from the solar wind charge exchange process using two large 4510 x 4510 pixel CCD370s as a focal plane. The CCD370s take their design and qualification heritage from similar sensors being used in the PLATO mission, with specific modifications to optimize their performance in this soft X-ray energy range. SMILE will orbit Earth in a highly elliptical orbit and will pass through the radiation belts every 52 hours. The trapped and solar protons present will gradually damage the CCDs throughout the 3-year mission and degrade their performance. To understand the impact the damage has on the devices a series of proton radiation campaigns are being undertaken. These campaigns are being performed with flight-like SMILE CCDs, and functionally similar PLATO devices, with follow-up characterization across from -130 to -85 °C. The most recent irradiation campaign has been completed using a PLATO CCD280 kept below -85 °C for irradiation and characterization, and the results show that the measured parallel charge transfer inefficiency varies with temperature between 1x10-4 and 4x10-4 in unbinned full-frame readout mode. The effect of temperature annealing up to -85 °C on the parallel charge transfer inefficiency has also been assessed and shows that no temperature-dependent annealing of the radiation-induced damage has been observed. A similar behavior is expected to be seen in the SMILE devices, albeit with an anticipated improvement by a factor 3-4 due to the modifications made to the design. Thus, results indicate the SMILE CCD370s will meet the performance requirements of the SMILE SXI instrument.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steven Parsons, David Hall, Andrew Holland, Peter Verhoeve, Steven Sembay, George Randall, Oliver Hetherington, Dean Yeoman, Thomas Buggey, and Matthew Soman "Radiation damage testing status of the CCDs for the SMILE SXI", Proc. SPIE 11454, X-Ray, Optical, and Infrared Detectors for Astronomy IX, 114540Q (13 December 2020); https://doi.org/10.1117/12.2560337
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Radiation effects

Charge-coupled devices

Cryogenics

Solar processes

Magnetosphere

X-rays

Satellite imaging

RELATED CONTENT

Soft x ray imaging with a newly designed large area...
Proceedings of SPIE (January 01 1900)
Processing x-ray data on board the SMILE SXI
Proceedings of SPIE (December 13 2020)
First evaluation of the CCD370 for the soft X ray...
Proceedings of SPIE (January 01 1900)
Imaging of x rays for magnetospheric investigations
Proceedings of SPIE (June 01 1992)
Advanced solar imaging from the GOES R spacecraft
Proceedings of SPIE (February 11 2003)

Back to Top