1 July 1990 Description of a simultaneous emission-transmission CT system
Bruce H. Hasegawa, Eric L. Gingold, Susan M. Reilly, Soo-Chin Liew, Christopher E. Cann
Author Affiliations +
Abstract
We are designing an instrument which will perform correlated emission-transmission image acquisition, but which departs from previous systems by incorporating a low-power x-ray tube and generator, rather than a radionuclide source, for the transmission image. The system uses an array of high-purity germanium (HPGe) detectors and detector electronics with energy discrimination circuitry to separate x-rays (at 100 or 120 kVp) from higher energy gamma rays from the 99mTc or 123j radiopharmaceutical injected into the patient. The data acquisition electronics have time constants matching the charge collection time (50 ns) of the HPGe detectors to maximize count-rate capabilities (up to 1 million cps per detector element), while maintaining adequate energy resolution (approximately 10% FWHM). Each detector channel has two energy windows for simultaneous transmission-emission imaging or for dual-energy x-ray studies. A host computer provides system control as well as data acquisition, data correction, tomographic image reconstruction, image display, and data analysis. As a radionuclide imaging system, this instrument will function as a single-slice SPECT scanner with high-count rate capabilities and excellent energy resolution for imaging short-lived radionuclides, improved photopeak discrimination and scatter rejection, and simultaneous imaging of multiple radionuclides. The system also will generate radiographic images in either a tomographic or projection scanning mode, while dual-energy x-ray CT will provide material specific imaging. However, the novel and potentially powerful capabilities of this instrument would derive from its inherent correlation of functional information from SPECT with precise anatomic information from CT or the material-specific morphologic information from dual-energy x-ray CT. The simultaneously acquired radiographic images should relieve the deficiencies of poor statistics and limited spatial resolution commonly associated with SPECT systems. Dual-energy xray CT also can provide an energy-corrected and anatomically-correlated map of attenuation coefficients for more accurate quantitation of emission radionuclide data.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bruce H. Hasegawa, Eric L. Gingold, Susan M. Reilly, Soo-Chin Liew, and Christopher E. Cann "Description of a simultaneous emission-transmission CT system", Proc. SPIE 1231, Medical Imaging IV: Image Formation, (1 July 1990); https://doi.org/10.1117/12.18783
Lens.org Logo
CITATIONS
Cited by 74 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Imaging systems

X-ray imaging

Signal attenuation

X-ray computed tomography

Data acquisition

Back to Top