Paper
30 May 1995 Flash x-ray generator having a liquid-anode diode
Teiji Oizumi, Eiichi Sato, Arimitsu Shikoda, Michiaki Sagae, Kei Takahashi, Yoshiharu Tamakawa, Toru Yanagisawa, Hidenori Ojima, Kazuyoshi Takayama, Akihiro Fujiwara, Kanji Mitoya
Author Affiliations +
Proceedings Volume 2513, 21st International Congress on: High-Speed Photography and Photonics; (1995) https://doi.org/10.1117/12.209673
Event: High-Speed Photography and Photonics: 21st International Congress, 1994, Taejon, Korea, Republic of
Abstract
The constructions and the fundamental studies of a flash x-ray generator having a liquid-anode diode are described. This flash x-ray generator consisted of the following essential components: a high-voltage power supply, a high-voltage pulser, a thyratron pulser as a trigger device, an oil diffusion pump, and a flash x-ray tube. The main condenser was negatively charged from 50 to 70 kV by the power supply, and the electric charges in the condenser were discharged to the x-ray tube after closing a gap switch by using the thyratron pulser. The flash x- ray tube was of a diode type having a mercury anode and a ferrite cathode. The pressure of the tube was primarily determined by the steam pressure of mercury as a function of temperature. The maximum output voltage from the pulser was about -1 times the charged voltage. The maximum tube voltage and current were approximately 60 kV and 3 kA, respectively, with a charged voltage of -60 kV and a space between the anode and cathode electrodes (AC space) of 2.0 mm. The pulse widths of flash x rays were about 50 ns, and the x-ray intensity measured by a thermoluminescence dosimeter had a value of about 2.5 (mu) C/kg at 0.3 m per pulse with a charged voltage of -70 kV and an AC space of 1.0 mm.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Teiji Oizumi, Eiichi Sato, Arimitsu Shikoda, Michiaki Sagae, Kei Takahashi, Yoshiharu Tamakawa, Toru Yanagisawa, Hidenori Ojima, Kazuyoshi Takayama, Akihiro Fujiwara, and Kanji Mitoya "Flash x-ray generator having a liquid-anode diode", Proc. SPIE 2513, 21st International Congress on: High-Speed Photography and Photonics, (30 May 1995); https://doi.org/10.1117/12.209673
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Radiography

Diodes

Virtual colonoscopy

Mercury

Electrodes

X-ray sources

RELATED CONTENT

High-speed soft x-ray generators in biomedicine
Proceedings of SPIE (May 30 1995)
Transformer-driven stroboscopic x-ray generator SX-T98
Proceedings of SPIE (June 22 1999)
Dual-energy flash x-ray generator
Proceedings of SPIE (May 30 1995)
High-speed soft x-ray techniques
Proceedings of SPIE (May 28 1997)

Back to Top