31 October 1996 Calibration of the AXAF-HRC UV/ion shields at the Osservatorio Astronomico di Palermo G.S. Vaiana: IV - UV rejection measurements
Marco Barbera, Alfonso Collura, Alessandro Dara, Salvatore Serio, Martin V. Zombeck
Author Affiliations +
Abstract
The AXAF-HRC UV/ion shields have to provide high UV rejection from diffuse background and bright UV sources (e.g. rejection greater than 107 at wavelength longer than approximately 300 angstrom for the HRC-I). In the framework of the AXAF-HRC calibration program we have conducted UV (300 - 2500 angstrom) and FUV/visible (1900 - 10,000 angstrom) transmission measurements on the baseline design UV/ion shields based on Lexan and aluminum. The results of these measurements, here reported, have shown that the baseline design UV/ion shields did not meet the scientific requirements of UV opacity and as a consequence, the UV/ion shields were redesigned. UV tests of new UV/ion shields, based on new materials, is in progress.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marco Barbera, Alfonso Collura, Alessandro Dara, Salvatore Serio, and Martin V. Zombeck "Calibration of the AXAF-HRC UV/ion shields at the Osservatorio Astronomico di Palermo G.S. Vaiana: IV - UV rejection measurements", Proc. SPIE 2808, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy VII, (31 October 1996); https://doi.org/10.1117/12.255987
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Aluminum

Ultraviolet radiation

Opacity

X-rays

Coating

Sensors

Calibration

Back to Top