Paper
31 December 1996 High-resolution laser scanning image system
Zhonghou Wang, Hengjin Zhang
Author Affiliations +
Proceedings Volume 2866, International Conference on Holography and Optical Information Processing (ICHOIP '96); (1996) https://doi.org/10.1117/12.263019
Event: International Conference on Holography and Optical Information Processing, 1996, Nanjing, China
Abstract
A high resolution laser scanning image system (HRLSIS) is introduced in this paper. A 7 element f(theta) lens is designed, which linear distortion is less than 0.04% and MTF of all fields more than 0.5. Using a optical compensation method, pyramidal error of the rotating prism is less than 1'. Performance achieved by the HRLSIS is: length of scanning line is 200, pixel count per line is 8000, position accuracy of adjacent pixels is less than 5 (mu) .
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhonghou Wang and Hengjin Zhang "High-resolution laser scanning image system", Proc. SPIE 2866, International Conference on Holography and Optical Information Processing (ICHOIP '96), (31 December 1996); https://doi.org/10.1117/12.263019