21 November 1997 Measurement of three-dimensional temperature field using phase-shifting holography and CT technique
Dufang Shi, Xudong Xiao, Yulong He, Peiwen Qiao, Shaohua Chen
Author Affiliations +
Abstract
The theory and experimental method of measuring flame temperature field with two-reference phase-shifting holographic interferometry and CT technique are studied in this paper. By recording the relative intensity distributions of three-step phase-shifting each view direction, we obtained the accurate phase distributions used to reconstruct the refractive index field. The cross section temperature field of a double-candle flame is measured, and the sources of experimental and other error are also discussed.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dufang Shi, Xudong Xiao, Yulong He, Peiwen Qiao, and Shaohua Chen "Measurement of three-dimensional temperature field using phase-shifting holography and CT technique", Proc. SPIE 3172, Optical Technology in Fluid, Thermal, and Combustion Flow III, (21 November 1997); https://doi.org/10.1117/12.293403