Paper
25 January 2002 Centroiding and point response function measurements of the mirror/detector combination for the x-ray telescope on the SWIFT gamma-ray burst explorer
Author Affiliations +
Abstract
The essential optical components of the Swift X-ray Telescope (XRT) are already developed items. They are: the flight spare x-ray mirror from the JET-X/Spectrum-X program and a MOS CCD (CCD22) of the type currently operating in orbit as part of the EPIC focal plane camera on the XMM- Newton. The JET-X mirrors were first calibrated at the Max Plank Institute for Extraterrestrial Physics' (MPE) Panter facility, Garching, Germany in 1996. Half energy widths (HEW) of 16 arc seconds at 1.5 keV were confirmed for the two flight mirrors and the flight spare. The calibration of the flight spare was repeated at Panter in July 2000 in order to establish whether any changes had occurred during the four years that the mirror had been in storage at the OAB, Milan, Italy. This results reported in this paper, confirm that the resolution of the JET-X mirrors has remained stable over this storage period. In an extension of this test program, the flight spare EPIC camera was installed at the focus of the JET-X mirror to simulate the optical system of the Swift X-ray telescope. On-axis and off-axis point spread functions (PSFs) were measured and calibration data sets were used to obtain centroid positions of X-ray point sources. The results confirmed Swift's ability to determine the centroid positions of sources at 100mCrab brightness to better than 1 arc second and provided a calibration of the centroiding process as a function of source flux and off axis angle. The presence of background events in the image frame introduced errors in the centroiding process, making the choice of centroiding algorithm important. Algorithm performance and the trade-off between processing speed and centroiding accuracy were investigated.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Richard M. Ambrosi, Anthony F. Abbey, Ian Hutchinson, Richard Willingale, Sergio Campana, Giancarlo Cusumano, Wolfgang Burkert, Alan A. Wells, Alexander T. Short, Oberto Citterio, Mauro Ghigo, G. Tagliaferri, and Heinrich W. Braeuninger "Centroiding and point response function measurements of the mirror/detector combination for the x-ray telescope on the SWIFT gamma-ray burst explorer", Proc. SPIE 4497, X-Ray and Gamma-Ray Instrumentation for Astronomy XII, (25 January 2002); https://doi.org/10.1117/12.454228
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Point spread functions

X-rays

Mirrors

Charge-coupled devices

Calibration

Cameras

Gamma radiation

Back to Top