22 April 2008 Development of a high flow-rate/high operating frequency nitinol MEMS valve
Author Affiliations +
Abstract
This paper presents modeling, fabrication, and testing results for a high flow-rate and high frequency Nitinol MEMS valve. ANSYS(R) is used to evaluate several Nitinol MEMS valve structural designs with the conclusion that a pentagonal flap with five legs produces higher frequencies and higher strengths without the inherent rotation problem present in standard designs. The Nitinol penta-leg design was fabricated using a novel bi-layer lift-off method. A PMGI polymer layer is initially used as an underlayer while a chromium layer is used as a top layer to produce a non-rotational ortho-planar Nitinol MEMS valve array. This array consists of 65 microvalves with dimensions of 1mm in circumference, 50 μm in leg width, and 8.2 μm in Nitinol thickness. Each microvalve covers an orifice of 220 μm in diameter and 500 μm in length and is capable of producing a 150 μm vertical deflection. This Nitinol MEMS valve array was tested for flow-rates in a hydraulic system as a function of applied pressure with a maximum water flow-rate of 16.44 cc/s.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Myunghoon Seong, K. P. Mohanchandra, Yohan Lin, and Gregory P. Carman "Development of a high flow-rate/high operating frequency nitinol MEMS valve", Proc. SPIE 6932, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2008, 69322F (22 April 2008); https://doi.org/10.1117/12.775812
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microelectromechanical systems

Actuators

Chromium

Finite element methods

Data modeling

Sensors

Silicon

Back to Top