Paper
17 June 2008 Calibration of laser vibrometers at frequencies up to 100 kHz and higher
Guillermo Silva Pineda, Hans-Jürgen von Martens, Sergio Rojas, Arturo Ruiz, Lorenzo Muñiz
Author Affiliations +
Proceedings Volume 7098, Eighth International Conference on Vibration Measurements by Laser Techniques: Advances and Applications; 70981K (2008) https://doi.org/10.1117/12.803338
Event: Eighth International Conference on Vibration Measurements by Laser Techniques: Advances and Applications, 2008, Ancona, Italy
Abstract
Manufacturers and users of laser vibrometers exploit the wide frequency and intensity ranges of laser techniques, ranging over many decades (e.g., from 0.1 Hz to 100 MHz). Traceability to primary measurement standards is demanded over the specified measurement ranges of any measurement instrumentation. As the primary documentary standard ISO 16063-11 for the calibration of vibration transducers is restricted to 10 kHz, a new international standard for the calibration of laser vibrometers, ISO 16063-41, is under development. The current stage of the 2nd Committee Draft (CD) of the ISO standard specifies calibration methods for frequencies from 0.4 Hz to 50 kHz which does not meet the demand for providing traceability at higher frequencies. New investigations will be presented which demonstrate the applicability of the laser interferometer methods specified in ISO 16063-11 and in the 2nd CD also at higher frequencies of 100 kHz and beyond. The three standard methods were simultaneously used for vibration displacement and acceleration measurements up to 100 kHz, and a fourth high-accuracy method has been developed and used. Their results in displacement and acceleration measurements deviated by less than 1 % from each other at vibration displacement amplitudes in the order of 100 nm. In addition to the three interferometer methods specified in ISO 16063-11 and 16063-15, and in the 2nd Committee Draft of 16063-41 as well, measurement results will be presented. Examples of laser vibrometer calibrations will bedemonstrated. Further investigations are aimed
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Guillermo Silva Pineda, Hans-Jürgen von Martens, Sergio Rojas, Arturo Ruiz, and Lorenzo Muñiz "Calibration of laser vibrometers at frequencies up to 100 kHz and higher", Proc. SPIE 7098, Eighth International Conference on Vibration Measurements by Laser Techniques: Advances and Applications, 70981K (17 June 2008); https://doi.org/10.1117/12.803338
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Standards development

Interferometers

Homodyne detection

Laser interferometry

Transducers

Helium neon lasers

Back to Top