Paper
13 March 2009 Exact and stable interior ROI reconstruction for radial MRI
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72585G (2009) https://doi.org/10.1117/12.812035
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
MRI applications often require high spatial and/or temporal resolution within a region of interest (ROI) such as for perfusion studies. In theory, both spatial resolution and temporal resolution can be significantly improved using a ROI-focused MRI data acquisition scheme. However, in radial MRI, there is no such acquisition-based solution available. Traditional reconstruction methods to image the ROI by reducing the field of view produce aliasing artifacts when the dataset becomes truncated. Here we propose an interior MRI methodology to perform ROI reconstruction without artifacts. Methods: In contrast to the conventional wisdom that the interior problem does not have a unique solution, interior tomography has been recently proposed as an exact and stable solution to this longstanding problem. In this project, a ROI-focused radial MRI data acquisition scheme was developed, aided by a dedicated digital filter. We implemented this method in a 4T 90 cm bore Oxford magnet with a GE phantom and a transceiver TEM head coil. The parameters were 4 gauss/cm sonata gradients, 5 mm slice thickness, TE=30 ms, TR=200 ms, FOVs of 40 cm and 12 cm respectively. Results: Both numerical simulation and phantom experiments have demonstrated that the proposed interior MRI method can exactly reconstruct a ROI with increased spatial resolution (~4 fold) while keeping the same temporal resolution. The image artifacts from truncated projections are effectively eliminated. No crosstalk with the outside ROI region is involved using the proposed method. Conclusions: Our interior radial MRI method can be used for zoomed-in and fast
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jie Zhang, Hengyong Yu, Curt Corum, Michael Garwood, and Ge Wang "Exact and stable interior ROI reconstruction for radial MRI", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72585G (13 March 2009); https://doi.org/10.1117/12.812035
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic resonance imaging

Tomography

Spatial resolution

Temporal resolution

Data acquisition

Digital filtering

Computed tomography

Back to Top