Paper
31 December 2010 Precise measurement of liquid petroleum tank volume based on data cloud analysis
Jintao Wang, Ziyong Liu, Long Zhang, Ligong Guo, Xuesong Bao, Lin Tong
Author Affiliations +
Proceedings Volume 7544, Sixth International Symposium on Precision Engineering Measurements and Instrumentation; 75444T (2010) https://doi.org/10.1117/12.885442
Event: Sixth International Symposium on Precision Engineering Measurements and Instrumentation, 2010, Hangzhou, China
Abstract
Metal tanks are generally used for the measurement of liquid petroleum products for fiscal or custody transfer application. One tank volume precise measurement method based on data cloud analysis was studied, which was acquired by laser scanning principle. Method of distance measurement by laser phase shift and angular measurement by optical grating were applied to acquire coordinates of points in tank shell under the control of a servo system. Direct Iterative Method (DIM) and Section Area Method (SAM) were used to process measured data for vertical and horizontal tanks respectively. In comparison experiment, one 1000m3 vertical tank and one 30m3 horizontal tank were used as test objects. In the vertical tank experiment, the largest measured radius difference between the new laser method and strapping method (international arbitrary standard) is 2.8mm. In the horizontal tank experiment, the calibration result from laser scanning method is more close to reference than manual geometric method, and the mean deviation in full-scale range of the former and latter method are 75L and 141L respectively; with the increase of liquid level, the relative errors of laser scanning method and manual geometric method become smaller, and the mean relative errors are 0.6% and 1.5% respectively. By using the method discussed, the calibration efficiency of tank volume can be improved.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jintao Wang, Ziyong Liu, Long Zhang, Ligong Guo, Xuesong Bao, and Lin Tong "Precise measurement of liquid petroleum tank volume based on data cloud analysis", Proc. SPIE 7544, Sixth International Symposium on Precision Engineering Measurements and Instrumentation, 75444T (31 December 2010); https://doi.org/10.1117/12.885442
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Laser scanners

Calibration

Liquids

Clouds

3D scanning

Data processing

Distance measurement

Back to Top