8 March 2013 Responses to amplitude modulated infrared stimuli in the guinea pig inferior colliculus
Author Affiliations +
Abstract
Responses of units in the central nucleus of the inferior colliculus of the guinea pig were recorded with tungsten electrodes. The set of data presented here is limited to high stimulus levels. The effect of changing the modulation frequency and the modulation depth was explored for acoustic and laser stimuli. The selected units responded to sinusoidal amplitude modulated (AM) tones, AM trains of clicks, and AM trains of laser pulses with a modulation of their spike discharge. At modulation frequencies of 20 Hz, some units tended to respond with 40 Hz to the acoustic stimuli, but only at 20 Hz for the trains of laser pulses. For all modes of stimulation the responses revealed a dominant response to the first cycle of the modulation, with decreasing number of action potential during successive cycles. While amplitude modulated tone bursts and amplitude modulated trains of acoustic clicks showed similar patterns, the response to trains of laser pulses was different.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Claus-Peter Richter and Hunter Young "Responses to amplitude modulated infrared stimuli in the guinea pig inferior colliculus", Proc. SPIE 8565, Photonic Therapeutics and Diagnostics IX, 85655U (8 March 2013); https://doi.org/10.1117/12.2013847
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation

Acoustics

Amplitude modulation

Electrodes

Action potentials

Ear

Infrared radiation

Back to Top