Paper
29 May 2013 Mid-wave infrared hyperspectral imaging of unknown chemical warfare agents
Author Affiliations +
Abstract
The ability of a stand-off chemical detector to distinguish two different chemical warfare agents is demonstrated in this paper. Using Negative Contrast Imaging, based upon IR absorption spectroscopy, we were able to detect 1 μl of VX, sulfur mustard and water on a subset of representative surfaces. These experiments were performed at a range of 1.3 metres and an angle of 45° to the surface. The technique employed utilises a Q-switched intracavity MgO:PPLN crystal that generated 1.4 – 1.8 μm (shortwave) and 2.6 – 3.6 μm (midwave) infrared radiation (SWIR and MWIR, respectively). The MgO:PPLN crystal has a fanned grating design which, via translation through a 1064 nm pump beam, enables tuning through the SWIR and MWIR wavelength ranges. The SWIR and MWIR beams are guided across a scene via a pair of raster scanned mirrors allowing detection of absorption features within these spectral regions. This investigation exploited MWIR signatures, as they provided sufficient molecular information to distinguish between toxic and benign chemicals in these proof-of-concept experiments.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Rhea J. Clewes, Chris R. Howle, Jason Guicheteau, Darren Emge, Keith Ruxton, Gordon Robertson, William Miller, Graeme Malcolm, and Gareth T. Maker "Mid-wave infrared hyperspectral imaging of unknown chemical warfare agents", Proc. SPIE 8710, Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XIV, 871002 (29 May 2013); https://doi.org/10.1117/12.2017868
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mid-IR

Sensors

Liquids

Metals

Short wave infrared radiation

Absorption

Infrared spectroscopy

Back to Top