Paper
16 December 1988 Preliminary Study Of Triple Photon Coincidence Imaging Technique
Z. Liang
Author Affiliations +
Abstract
Preliminary study of triple photon coincidence imaging technique (TPCIT) is presented for two imaging modes of angular unconstrained and constrained coincidence triple photons. The angular unconstrained triple photon coincidence mode reconstructs source distribution by small source volume fields (z 1.0 x 1.0 x 1.0 cm 3), each of which is specified by the intersection of three hollow cones generated from a triple photon coincidene event. Each hollow cone represents a source probability field of a photon undergoing an electronic collimation of scattering-absorption process. The angular constrained triple photon coincidence mode determines two small source volume fields from each triple photon coincidence event. The two volume fields are specified by the intersections of a hollow cone generated by a photon and a solid cylinder generated by another two photons from a positron annihilation with 180 degrees constaint. A truncated spherical detector system for brain imaging studies is proposed for quantitative analysis on resolution, sensitivity, and signal to noise ratio. The nuclear isoto,Re of Hf ;12 for the angular unconstrained TPCIT and Cs lgi for the angular constrained TPCIT are among many other isotopes, used for quantitative calculation. A comparison of the proposed imaging system with customary SPECT and PET is reported.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Z. Liang "Preliminary Study Of Triple Photon Coincidence Imaging Technique", Proc. SPIE 0974, Applications of Digital Image Processing XI, (16 December 1988); https://doi.org/10.1117/12.948469
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Solids

Spatial resolution

Spherical lenses

Signal to noise ratio

Positron emission tomography

Single photon

RELATED CONTENT

Observer performance in multi-technology imaging
Proceedings of SPIE (January 01 1900)
Multi-modality systems for molecular tomographic imaging
Proceedings of SPIE (November 25 2009)
Advantages of semiconductor CZT for medical imaging
Proceedings of SPIE (September 28 2007)
HyperSPECT a new system for pre clinical imaging in...
Proceedings of SPIE (March 13 2009)

Back to Top