1 September 2020 NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance
Author Affiliations +
Abstract

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9  μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

© 2020 Society of Photo-Optical Instrumentation Engineers (SPIE) 1931-3195/2020/$28.00 © 2020 SPIE
Hongda Chen, Xiaoxiong Xiong, Daniel O. Link, Chengbo Sun, and Kwofu V. Chiang "NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance," Journal of Applied Remote Sensing 14(3), 034516 (1 September 2020). https://doi.org/10.1117/1.JRS.14.034516
Received: 23 March 2020; Accepted: 11 August 2020; Published: 1 September 2020
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Sensors

Infrared imaging

Radiometry

Visible radiation

Magnesium

Signal to noise ratio

Back to Top