Open Access
15 March 2018 Correcting for motion artifact in handheld laser speckle images
Ben Lertsakdadet, Bruce Y. Yang, Cody E. Dunn, Adrien Ponticorvo, Christian Crouzet, Nicole Bernal M.D., Anthony J. Durkin, Bernard Choi
Author Affiliations +
Abstract
Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by <4 %   when accounting for motion artifact using the FM, which is less than the speckle contrast difference between superficial and full thickness burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.
© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE) 1083-3668/2018/$25.00 © 2018 SPIE
Ben Lertsakdadet, Bruce Y. Yang, Cody E. Dunn, Adrien Ponticorvo, Christian Crouzet, Nicole Bernal M.D., Anthony J. Durkin, and Bernard Choi "Correcting for motion artifact in handheld laser speckle images," Journal of Biomedical Optics 23(3), 036006 (15 March 2018). https://doi.org/10.1117/1.JBO.23.3.036006
Received: 17 October 2017; Accepted: 21 February 2018; Published: 15 March 2018
Lens.org Logo
CITATIONS
Cited by 29 scholarly publications and 7 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fermium

Frequency modulation

Speckle

Blood circulation

Data acquisition

Motion measurement

In vivo imaging

RELATED CONTENT


Back to Top