1 June 1995 Linear polarization uniformity measurements taken with an imaging polarimeter
Author Affiliations +
Abstract
Four types of polarizers are experimentally evaluated and compared for the uniformity of their transmission axis orientations and the contrast ratio and their spatial variation. Representative samples of calcite Glan-Thompson polarizers, polarizing beamsplitters, silver glass polarizers, and stretched polymer polarizers are characterized at 850 nm using a rotating polarizer imaging polarimeter. The sample Glan-Thompson polarizers show the highest contrast ratios and greatest uniformity of transmission axis. Silver glass polarizers and stretched polymer polarizers show intermediate contrast ratios, but all samples of both show a systematic variation of the transmission axis orientation with a magnitude of several tenths of a degree. The polarizing beamsplitter cube samples have very good uniformity of transmission axis but the smallest contrast ratios with noticeable spatial variations of contrast.
J. Larry Pezzaniti and Russell A. Chipman "Linear polarization uniformity measurements taken with an imaging polarimeter," Optical Engineering 34(6), (1 June 1995). https://doi.org/10.1117/12.202070
Published: 1 June 1995
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Polarizers

Glasses

Polymers

Silver

Beam splitters

Polarization

Polarimetry

RELATED CONTENT


Back to Top