Optoelectronics techniques to induce protoporphyrin IX fluorescence with topically applied 5-aminolevulinic acid on the oral mucosa have been developed to noninvasively detect oral cancer. Fluorescence imaging enables wide-area screening for oral premalignancy, but the lack of an adequate fluorescence enhancement method restricts the clinical imaging application of these techniques. This study aimed to develop a reliable fluorescence enhancement method to improve PpIX fluorescence imaging systems for oral cancer detection. Three contrast features, red-green-blue reflectance difference, R/B ratio, and R/G ratio, were developed first based on the optical properties of the fluorescence images. A comparative study was then carried out with one negative control and four biopsy confirmed clinical cases to validate the optimal image processing method for the detection of the distribution of malignancy. The results showed the superiority of the R/G ratio in terms of yielding a better contrast between normal and neoplastic tissue, and this method was less prone to errors in detection. Quantitative comparison with the clinical diagnoses in the four neoplastic cases showed that the regions of premalignancy obtained using the proposed method accorded with the expert's determination, suggesting the potential clinical application of this method for the detection of oral cancer.
We investigate the possibility of using ALA-derived PpIX fluorescence spectroscopy for the detection of epithelial hyperkeratosis (EH) or epithelial dysplasia (ED) lesions in oral submucous fibrosis (OSF) patients that could not be found by autofluorescence spectroscopy. Twenty percent of ALA solution gel was applied onto oral neoplasia and surrounding normal tissue [normal oral mucosa (NOM)] for 90 min. Fluorescence emission spectra were measured under 410 nm excitation. Generally, the most intense fluorescence emission peaks occurred at 460 and 630 nm. The ratios of the area under red peak (630±10 nm) to the area under blue peak (460±10 nm), denoted as R/B, were calculated. We found that OSF mucosa has the lowest R/B value, followed by NOM, EH on OSF, and ED on OSF. An ANOVA test showed significant differences between OSF, NOM, EH on OSF, and ED on OSF (p<0.05). However, measurements of autofluorescence (i.e., before ALA application) show no significant differences between OSF, NOM, EH on OSF, and ED on OSF (ANOVA test, p>0.05). These results indicate that ALA-induced PpIX fluorescence spectroscopy could be used to identify the premalignant lesions on oral fibrotic mucosa, which could not be found by autofluorescence.
An in vivo study of human oral cancer diagnosis by using autofluorescence spectroscopy is presented. A Xenon-lamp with a motor-controlled monochromator was adopted as the excitation light source. We chose the excitation wavelength of 330 nm, and the spectral measurement range was from 340 nm to 601 nm. A Y-type fiber bundle was used to guide the excitation light, and collect the autofluorescence of samples. The emitted light was detected by a motor-controlled monochromator and a PMT. After measurement, the measured sites were sectioned and sent for histological examination. In total 15 normal sites, 30 OSF (oral submucosa fibrosis) sites, 26 EH (epithelial hyperkratosis) sites, 13 ED (epithelial dysplasia) sites, and 13 SCC (squamous cell carcinoma) sites were measured. The discriminant algorithm was established by partial-least squares (PLS) method with cross-validation technique. By extracting the first two t-scores of each sample and make scattering plot, we found that the samples of different cancerous stages were in grouped distinct locations, except that samples of ED and EH were mixed together. It means that this algorithm can be used to classify normal, premalignant, and malignant tissues. We conclude that autofluorescence spectroscopy may be useful for in vivo detection of early stage oral cancer.
A study on in vivo measurement of autofluorescence spectra for hamster buccal pouch and development of oral carcinogenesis identification algorithm is presented. The measurement was preceded with a fiber-optics based fluorescence spectroscopy system. In total 75 samples, including 14 hyperkratosis, 23 normal, 28 dysplasia, and 10 SCC, were separated into 4 categories. All the spectra were normalized to have the same area below the spectrum curve. The results show that the autofluorescence spectra start to change as soon as the tissues have morphological alternation (eg hyperkratosis). The differences of ratios between the areas under 380+/- 15 nm and 460+/- 15 nm (denoted as A380+/- 15/ A460+/- 15) among categories are statistically significant. To develop a diagnostic algorithm for early neoplasia detection and evaluate its performance, a PLS discriminant analysis with cross-validation technique was proceeded. Sample points on the PLS score plot were grouped as four categories. By selecting suitable threshold, the accuracy rates for classifying 4 categories of samples are 86% (hyperkratosis), 87% (normal), 90% (dysplasia), and 100% (SCC), respectively. The results reveal that the autofluorescence spectroscopy technique is potential for in vivo detection of early neoplasia of oral tissues.
Photons are seriously scattered when entering turbid medium; this the images of objects hidden in turbid medium can not be obtained by just collecting the transmitted photons. Early-arriving photons, which are also called ballistic or snake protons, are much less scattered when passing through turbid medium, and contains more image information than the late-arriving ones. Therefore, objects embedded in turbid medium can be imaged by gathering the ballistic and snake photons. In the present research we try to recover images of objects in turbid medium by simultaneously time-gate and polarization-gate to obtain the snake photons. An Argon-pumped Ti-Sapphire laser with 100fs pulses was employed as a light source. A streak camera with a 2ps temporal resolution was used to extract the ballistic and snake photons. Two pieces of lean swine meat, measured 4mmX3mm and 5xxX4mm, respectively, were placed in a 10cmX10cmX3cm acrylic tank, which was full of diluted milk. A pair of polarizer and an analyzer was used to extract the light that keeps polarization unchanged. The combination of time gating and polarization gating resulted in good images of objects hidden in turbid medium.
Imaging of inhomogeneities in a turbid medium with transmitted optical signal represents a crucial technique for optical diagnosis of abnormal cells in human tissues, particularly important for early detection of female breast cancer. In this paper, we present the results of our simulation and experimental studies. In the simulation study, we propose a new technique using transient diffuse photon density waves for imaging reconstruction. In the experimental study, we demonstrate the assistance of ultrasounds to optical imaging through a turbid medium. For the imaging, we basically utilize transmitted ballistic and snake photons.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.