In this paper, we present our approach regarding the compensation of defective pixels in the infrared array detector used in the NINJA spectrograph for the Subaru Telescope. While it is typical to use a detector with minimal defective pixels for infrared spectrographs, our HAWAII-2RG detector has a central area with a defective pixel rate of 10%. Therefore, we compensate for defective pixels by mechanically shifting the detector along the focal plane in the direction of dispersion. This approach applies the concept of dithering in imaging observation to a spectrograph, and the shifting mechanism is designed to have a maximum movement distance of 8 mm. We present the expected performance of the compensation and the actual mechanical structure fabricated.
This conference presentation was prepared for the Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation V conference at SPIE Astronomical Telescopes + Instrumentation, 2022.
Near-INfrared and optical Joint spectrograph with Adaptive optics (NINJA) is an optical to near-infrared (NIR) spectrograph optimized for the laser tomography adaptive optics (LTAO) system at the Subaru telescope, realized by the adaptive secondary mirror and four-laser guide star (LGS) system now under development. One of the primary science objectives of this spectrograph is wide-band spectroscopic follow-up of transient sources like GRB, supernovae, or gravitational wave sources down to 22 mag in the J -band. NINJA consists of two spectrograph units, one is in the optical (0.35-0.85 µm) and the other in the NIR (0.85-2.5 µm), and a fore-optics which splits the light from the telescope to the spectrographs and wavefront sensors (WFSs) of LTAO. Each spectrograph has a slit with 0.35′′ wide and 5′′ long, and a spectral resolution of R=3000-4000 utilizing a grating. The four LGSs are planned to be arranged on a circle around the slit with a radius of about 8′′, and a patrol field of view (FoV) of a tip-tilt guide star is about 2′ diameter. With two dichroic mirrors, the fore-optics splits the light of the FoV into three wavelength ranges of 0.35-0.85 µm, 0.85-2.5 µm, and 0.589 µm for LGS. In this paper, we report the overall system of NINJA and a conceptual design of the optics.
MIMIZUKU is the first-generation mid-infrared instrument for the TAO 6.5-m telescope. It has three internal optical channels to cover a wide wavelength range from 2 to 38 µm. Of the three channels, the NIR channel is responsible for observations in the shortest wavelength range, shorter than 5.3 µm. The performance of the NIR channel is evaluated in the laboratory. Through the tests, we confirm the followings: 1) the detector (HAWAII 1RG with 5.3-µm cutoff) likely achieves ∼80% quantum efficiency; 2) imaging performance is sufficient to achieve seeing-limit spatial resolution; 3) system efficiencies in imaging mode are 2.4–31%; and 4) the system efficiencies in spectroscopic modes is 5–18%. These results suggest that the optical performance of the NIR channel is achieved as expected from characteristics of the optical components. However, calculations of the background levels and on-sky sensitivity based on these results suggest that neutral density (ND) filters are needed to avoid saturation in L ′ - and M′ -band observations and that the ND filters and the entrance window, made of chemical-vapor-deposition (CVD) diamond, significantly degrade the sensitivity in these bands. This means that the use of different window materials and improvements of the detector readout speed are required to achieve both near-infrared and long-wavelength mid-infrared (>30 µm) observations.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.