Paper
9 August 1983 High-Speed Cineradiographic System For Biomechanics Impact Research
M. Bender, N. Alem, G. Nusholtz, J. W. Melvin, W. L. Rogers
Author Affiliations +
Proceedings Volume 0312, 1st European Conf on Cineradiography with Photons or Particles; (1983) https://doi.org/10.1117/12.932923
Event: 1st European Conference on Cineradiography with Photons or Particles, 1981, Paris, France
Abstract
A high-speed 16-mm cineradiographic system previously developed at the University of Michigan, Highway Safety Research Institute, for use in biosciences research has been upgraded in capability by 1) increasing the x-ray field to 35-cm (14-in) by 43-cm (17-in), 2) incorporating a 35-mm high-speed motion picture to increase resolution, and 3) acauisition of a second x-ray head for three-dimensional x-ray stereophotogrammetric studies. This system now consists of a 35-mm Photosonics 4B camera, capable of 2500 frames per second, which views a 50-mm (2-in) diameter output phosphor of a highgain, 4-stage, magnetically focused image intensifier tube, gated on and off synchronously with the motion picture camera. A lens optically couples the input photocathode of the image tube to x-ray fluorescent (rare earth) anteelnimages produced by a smoothed d-c x-ray generator of a conventional type. The system is capable of a wide range of magnification ratios.
© (1983) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Bender, N. Alem, G. Nusholtz, J. W. Melvin, and W. L. Rogers "High-Speed Cineradiographic System For Biomechanics Impact Research", Proc. SPIE 0312, 1st European Conf on Cineradiography with Photons or Particles, (9 August 1983); https://doi.org/10.1117/12.932923
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
Back to Top