Paper
18 December 2019 A testing system of analyzing reliability induced by the FOG coil
Author Affiliations +
Proceedings Volume 11340, AOPC 2019: Optical Fiber Sensors and Communication; 1134005 (2019) https://doi.org/10.1117/12.2538967
Event: Applied Optics and Photonics China (AOPC2019), 2019, Beijing, China
Abstract
On the base of an analyzing system, we demonstrate a testing method to reveal whether the FOG scale factor is stability after a long term ageing. The temperature of the chamber is set to 85°C in order to accelerate ageing of the adhesive. The FOG scale factor data is sampled each month. Results show that the MTTF (Mean Time to Failure) of the FOG coils is not satisfied with the application need. The analyzing system has good application prospects in testing the instabilities of the FOG’s Scale Factor.
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bo-han Liu, Wen-long Zuo, Xiao-le Wu, and Yue-ze Wang "A testing system of analyzing reliability induced by the FOG coil", Proc. SPIE 11340, AOPC 2019: Optical Fiber Sensors and Communication, 1134005 (18 December 2019); https://doi.org/10.1117/12.2538967
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fiber optic gyroscopes

Reliability

Analytical research

Navigation systems

Adhesives

Chemical oxygen iodine lasers

Failure analysis

Back to Top