Photoacoustic tomography is a new medical imaging technology with the advantages of high resolution, high contrast and high penetration depth. There are three common photoacoustic imaging methods in practical applications: photoacoustic microscopic imaging (PAM), photoacoustic computed tomography (PACT), photoacoustic tomography (PAE). As an important branch of photoacoustic imaging, photoacoustic microimaging combines high contrast of optical imaging with high resolution of ultrasonic imaging. In photoacoustic microimaging system, acoustooptic coupling prism is a very important component, which is usually composed of irregular prism and spherical concave acoustic lens at the bottom. Its function is to carry out optical transmission and ultrasonic detection. The ultrasonic depth of field of spherical concave acoustic lens is limited. In order to overcome this defect, researchers propose to use conical concave acoustic lens to produce Bessel sound beam to realize large depth of field ultrasonic detection. But the conical concave acoustic lens affects laser focusing and imaging. In order to solve this problem, we propose an optimization method to eliminate the influence of conical concave acoustic lens on beam transmission. A calibration mirror is added to the acoustooptic coupling prism with conical concave acoustic lens at the bottom, and the deterioration of the cone concave acoustic lens to the beam transmission is eliminated by optimizing the surface shape and thickness of the calibration mirror by Zemax. The optimization effect is evaluated by analyzing the spot. The simulation results show that the optimization method can eliminate the influence of the conical concave acoustic lens on the beam transmission, make the focal point and the focal point keep the coaxial focus, and improve the detection efficiency of the photoacoustic signal. This work is of theoretical significance for the systematic study of large depth of field photoacoustic microimaging.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xianlin Song, Zouhua Chen, Qiming He, Jianshuang Wei, and Lingfang Song "Optimization method to eliminate the influence of the conical acoustic lens on the transmission of laser beam using ZEMAX", Proc. SPIE 11525, SPIE Future Sensing Technologies, 115252O (8 November 2020); https://doi.org/10.1117/12.2584877
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Acoustics

Zemax

Photoacoustic microscopy

Photoacoustic tomography

Prisms

Ultrasonics

Image resolution

Back to Top