Abstract
In order to control organic coating thickness on a steel sheet, two types of coating thickness gauges using a new method and the Brewster angle method have been developed for on-line monitoring. The new gauge has an on-line accuracy of +/- 0.2 micrometers and the Brewster angle method gauge has an on-line accuracy of +/- 0.1 micrometers . A portable oil thickness gauge has been developed to measure the oil thickness easily in various places.