Abstract
A method of image registration is presented for the case when the deformation between two images can be well approximated with a combination of translation, rotation, and global scaling. The method achieves very high accuracy by combining a global optimization in the 4- dimensional discrete parameter space with a local optimization in the 4-dimensional continuous parameter space. The 4-dimensional global optimization is accomplished with two 2- dimensional optimizations. The Fourier magnitude is used to decouple translation from rotation and scaling, and a log-polar mapping of the Fourier magnitude is used to convert rotation and scaling into shifts. Optimal rotation and scaling parameters are determined with a cross-correlation in the log-polar domain. After compensation for rotation and scaling differences, cross-correlation in the spatial domain yields the translation parameters. The four registration parameters are further refined with a local optimization using the correlation coefficient as a similarity measure in the 4-dimensional continuous parameter space. Results are shown from simulations and from registration of retinal images. For simulated images with a signal-to-noise ratio of -5 dB, the accuracy of the registration method is estimated to be better than 0.07 degrees, 0.1%, and 0.3 pixels for rotation, scaling, and translation, respectively. In the case of 512 X 512 pixel images the computation resource requirements are compatible with high end PCs, i.e., approximately 25 minutes on an Intel 80486/33 MHz based IBM/PC compatible.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Artur V. Cideciyan, Samuel G. Jacobson, Colin M. Kemp, Robert W. Knighton, and Joachim H. Nagel "Registration of high-resolution images of the retina", Proc. SPIE 1652, Medical Imaging VI: Image Processing, (1 June 1992); https://doi.org/10.1117/12.59439
Lens.org Logo
CITATIONS
Cited by 40 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

Signal to noise ratio

Photography

Medical imaging

Image processing

Eye

Retina

RELATED CONTENT

A single pixel camera video ophthalmoscope
Proceedings of SPIE (February 15 2017)
Application of a Plumbicon TV camera tube in a 2000...
Proceedings of SPIE (May 01 1994)
The Vidicon As A Radiometric Sensor
Proceedings of SPIE (September 26 1965)
Dynamic focus window selection strategy for digital cameras
Proceedings of SPIE (February 23 2005)
Registration of ophthalmic images using control points
Proceedings of SPIE (March 19 2003)

Back to Top