Paper
12 November 1993 Application of cylindrical hypervapotron for cooling of DIII-D ECH dummy loads
Chandrakant B. Baxi, John L. Doane
Author Affiliations +
Abstract
An application of the cylindrical HV to cool dummy loads of electron cyclotron heating (ECH) systems of the DIII-D fusion machine is presented. These devices are subjected to heat fluxes of several hundred W/cm2 and can be cooled by water. Analysis shows that HV cooling can handle the heat fluxes without exceeding temperature limits. The cylindrical HV may also be used for cooling of fusion diverters.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chandrakant B. Baxi and John L. Doane "Application of cylindrical hypervapotron for cooling of DIII-D ECH dummy loads", Proc. SPIE 1997, High Heat Flux Engineering II, (12 November 1993); https://doi.org/10.1117/12.163819