Paper
28 July 1994 Laser damage in MWIR MCT detectors
Author Affiliations +
Abstract
The amounts of 4 micron pulsed laser fluence necessary to induce one and two orders of magnitude degradation in the R0A value of Hg0.7Cd0.3Te at 100 K have been calculated. The R0A values used in this calculation were obtained by simultaneously including generation-recombination, diffusion and tunneling mechanisms.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vaidya Nathan "Laser damage in MWIR MCT detectors", Proc. SPIE 2114, Laser-Induced Damage in Optical Materials: 1993, (28 July 1994); https://doi.org/10.1117/12.180944
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Solar energy

Sensors

Mid-IR

Laser induced damage

Pulsed laser operation

Absorption

Phonons

Back to Top