Paper
8 April 1996 Dynamics of intramyocardial blood volume in the intact animal: evaluation with SPECT
Thomas Behrenbeck, Michael K. O'Connor, David A. Foley, Erik Leo Ritman M.D.
Author Affiliations +
Abstract
Variations in blood volume in the myocardium through the cardiac cycle have previously been considered constant. More recent studies have indicated a considerably variation from end diastole to end systole. These studies were nearly all performed under non-physiological conditions using muscle preparations or ex situ cardiac preparations. This study was designed to assess the dynamic changes of the intramyocardial blood volume in the intact animal under normal flow conditions using single photon emission computed tomography (SPECT). Radiolabeled, 15 micrometers diameter, microspheres were emoblized in the myocardial microcirculation of dogs with subsequent scans in a TRIAD single-photon-emission-computed- tomography scanner. Gated images were obtained at 63 msec intervals encompassing the entire heart. Transmural voxel (equals volume element) brightness was measured in all tomographic images reflecting global and regional count density in the myocardium. There was a significant decrease in the blood volume from end diastole to end systole (10.8 cc/100 mL muscle volume; p < 0.00001). The decrease from diastole (ED) to systole (ES) in image brightness at the apex, mid ventricle, and base were: -5.7% (p < 0.01, apex vs. base), -4.7% (p < 0.01, mid ventricle vs. base) and +2.2%, respectively. Conclusions: (1) respiratory and ECG gated SPECT images allow measurement of intramyocardial blood volume changes throughout the cardiac cycle in the intact animal; (2) myocardial blood content is maximum at ED; (3) these findings progressively diminished in magnitude from apex to base.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thomas Behrenbeck, Michael K. O'Connor, David A. Foley, and Erik Leo Ritman M.D. "Dynamics of intramyocardial blood volume in the intact animal: evaluation with SPECT", Proc. SPIE 2709, Medical Imaging 1996: Physiology and Function from Multidimensional Images, (8 April 1996); https://doi.org/10.1117/12.237876
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood

Single photon emission computed tomography

Heart

Signal attenuation

Electrocardiography

Scanners

In vivo imaging

Back to Top