Paper
1 September 1996 The choice of the photo-senitive detection systems for use in triangulation based optical microtopographers
Author Affiliations +
Proceedings Volume 2778, 17th Congress of the International Commission for Optics: Optics for Science and New Technology; 2778FR (1996) https://doi.org/10.1117/12.2316256
Event: 17th Congress of the International Commission for Optics: Optics for Science and New Technology, 1996, Taejon, Korea, Republic of
Abstract
Non invasive topographic characterization of rough surfaces is of major interest in the industrial world.

For some years we are dealing with the development of inspection's systems able to cope in a simple accurate and reliable way with the specific requirements herein involved. Our systems are based on a discreet triangulation procedure where the topographic information is obtained from the horizontal shift incurred by the bright spot created, by an oblique collimated light beam, on a surface when it is displaced vertically. A laser beam is focused onto a small, diffraction limited, spot on the surface and is made to scan it over the desired region. The sample is placed on XY high accuracy step motion table to perform the scanning of the sample' areas of interest. The bright spot is perpendicularly imaged onto a photo-sensitive detection system and its position obtained. The corresponding horizontal spot's shift on the reference plane is then computed. At each sampled point the distance between the surface and a reference plane is then easily calculated allowing the calculation of statistical surface characterization parameters and the tridimensional reproduction of surface's relief.

The decision about the right photo-sensitive detection system is our major concern in this communication. Special attention is paid to the use of CCD's linescan cameras and of the so called PSD's identifying the specific inspection situations where each one represents the best choice.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Manuel F. M. Costa "The choice of the photo-senitive detection systems for use in triangulation based optical microtopographers", Proc. SPIE 2778, 17th Congress of the International Commission for Optics: Optics for Science and New Technology, 2778FR (1 September 1996); https://doi.org/10.1117/12.2316256
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
Back to Top