9 May 1997 Helical CT study of cerebral perfusion and related hemodynamic parameters
Aleksa Cenic, Ting-Yim Lee, Rosemary A. Craen, Adrian W. Gelb
Author Affiliations +
Abstract
A convenient method for assessing cerebral perfusion and related functional parameters has been developed using a third generation slip-ring CT scanner. Dynamic contrast- enhanced scanning at the same level was employed to image the cerebral circulation at the rate of 1 image per second. Using data acquired with this non-helical mode of scanning, we have developed a method for the simultaneous in-vivo determination of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). These measurements are given in the same physiological units as positron emission tomography. In order to obtain accurate measurements of these parameters, methods were also developed to correct for recirculation and partial volume averaging in imaging small blood vessels. We have used 6 New Zealand white rabbits in our studies. For each rabbit, up to 3 CT measurements of CBF, CBV, and MTT were made at normocapnia under isoflurane anesthesia. Coronal sections through the brain were imaged while simultaneously imaging either a brain artery or the ear artery. Images were acquired for 1 minute as Isovue 300 was injected intravenously. In the acquired CT images, regions of interest in brain parenchyma and an artery were drawn. For each region of interest, the mean CT number in pre-contrast images was subtracted from the mean in post-contrast images to calculate the contrast concentration curves for the brain regions Q(t) and the arterial region Ca(t). Using a robust deconvolution method, the MTT was determined. CBV was then determined from the ratio of the areas of Q(t) and Ca(t). Finally, CBF was calculated from the Central Volume Principle. The mean regional CBF, CBV and MTT values were 73.3 +/- 5.1 ml/min/100g, 1.93 +/- 0.12 ml/100g and 1.80 +/- 0.18 s respectively. IN order to validate our CT CBF measurements, we also measured CBF using the well- established technique of microspheres with each CT study. The feasibility of our CT method to measure CBF accurately was demonstrated by an almost one-to-one correspondence between CT CBF and microspheres CBF measurements. The slope of the linear regression line between the two sets of CBF measurements was 0.97 +/- 0.03 with a correlation coefficient of 0.837.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Aleksa Cenic, Ting-Yim Lee, Rosemary A. Craen, and Adrian W. Gelb "Helical CT study of cerebral perfusion and related hemodynamic parameters", Proc. SPIE 3033, Medical Imaging 1997: Physiology and Function from Multidimensional Images, (9 May 1997); https://doi.org/10.1117/12.274052
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-ray computed tomography

Brain

Computed tomography

Arteries

Blood

Neuroimaging

Scanners

Back to Top