Paper
18 May 1999 Long-term health monitoring of an advanced polymer composite bridge
Harry W. Shenton III, Michael J. Chajes
Author Affiliations +
Abstract
A long-term, structural health monitoring system has been designed and installed on the firs polymer composite bridge to be built in Delaware. The system is designed to monitor and record strains and deflections of the bridge, and the temperature and humidity of the surrounding area. Two types of information are gathered, 'monitor' data and 'event' data. The monitor data records very slow gradual changes in the bridge behavior, while the event data captures the bridge response due to truck loads. The system has been on- line since June, 1998. Sample result are presented in the paper of event and monitor data. The event data shows that the transverse strain of the deck is greater than the longitudinal strain, by a factor of about 1.5, and that the absolute deflection of the deck at mid-span is due mostly to the deflection of the edge girder. Monitor data from a one month period is presented that shows the thermal variations in strain due to daily temperature changes, and the gradual, changes due to the average daily temperature. The long-term monitoring system should provide valuable data for assessing the long-term performance and durability of this unique polymer composite bridge.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Harry W. Shenton III and Michael J. Chajes "Long-term health monitoring of an advanced polymer composite bridge", Proc. SPIE 3671, Smart Structures and Materials 1999: Smart Systems for Bridges, Structures, and Highways, (18 May 1999); https://doi.org/10.1117/12.348664
Lens.org Logo
CITATIONS
Cited by 13 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Bridges

Composites

Wheatstone bridges

Data acquisition

Polymers

Computing systems

Sensors