Paper
18 December 2000 X-ray lateral migration radiography system for the application of land mine detection
Zhong Su, Alan M. Jacobs, Edward T. Dugan, Dan Ekdahl
Author Affiliations +
Abstract
X-ray lateral migration radiography generate images of land mines and other objects buried with less than 10 cm of overlaying soil. An x-ray pencil beam illuminates the object area pixel-by-pixel, and a detector array of two collimated and two collimated, large area, scintillators respectively register once-scattered and multiple-scattered photons from mines, other buried objects, and the soil background. Two surface-feature-dominant uncollimated detector images and two subsurface-feature-dominant collimated detector images are typically generated. In the collimated detector images, a shifting of the images from the object center is proportional to the depth-of-burial of the detected object. Real mine test have been conducted and the images show the included air volume as a prominent feature. The combination of the geometrically regular air volumes and mine case present unique features which distinguish mine from nonmine objects. In fact, identification of some land mine types can be achieved from the acquired images. A field-test version of the system, to be used as a landmine object confirmation/identification detector is under construction. The completed generator/collimator x-ray source has been employed to produce the system-design raster direction of the incident photon beam, while 1D movement of the object is temporarily employed to simulate the orthogonal image axis. Easily recognized acquired images of the test object clearly indicate that the desired pixel dwell time of 0.01 sec has been achieved. This image acquisition speed translates into approximate values of 1.8 sec for a 20 by 20 cm interrogated area, consistent with scanning an antipersonnel mine, and 16 sec for a 60 by 60 cm area, consistent with an antitank mine.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhong Su, Alan M. Jacobs, Edward T. Dugan, and Dan Ekdahl "X-ray lateral migration radiography system for the application of land mine detection", Proc. SPIE 4142, Penetrating Radiation Systems and Applications II, (18 December 2000); https://doi.org/10.1117/12.410558
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Land mines

Mining

X-rays

Collimation

Radiography

Sensors

Image sensors

Back to Top