Paper
5 October 2000 Novel pressure sensor with a Fabry-Perot interferometer
Zhiquan Li, Lina Fan, Xifu Qiang
Author Affiliations +
Proceedings Volume 4223, Instruments for Optics and Optoelectronic Inspection and Control; (2000) https://doi.org/10.1117/12.401773
Event: Optics and Optoelectronic Inspection and Control: Techniques, Applications, and Instruments, 2000, Beijing, China
Abstract
A novel pressure sensor using a fiber Fabry-Perot interferometer (FFPI) has been developed in this paper. We use the internal F-P cavity pressure sensor in our research. Micromachined Fabry-Perot microcavity structures have been investigated for use as a pressure sensor. The single-mode fiber containing the interferometer is bonded at one end to the stainless-steel diaphragm and is also attached under longitudinal tension beyond the interferometer. An analysis relating the expected interferometer phase change to pressure is presented. And the dynamic response of FFPI sensor to pressure changes produced by an air pump is in good agreement with that measured with a conventional pressure sensor. The sensor is suitable for operation with other signal-processing and multiplexing schemes.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhiquan Li, Lina Fan, and Xifu Qiang "Novel pressure sensor with a Fabry-Perot interferometer", Proc. SPIE 4223, Instruments for Optics and Optoelectronic Inspection and Control, (5 October 2000); https://doi.org/10.1117/12.401773
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Fabry–Perot interferometry

Fiber optics sensors

Interferometers

Single mode fibers

Mirrors

Fabry–Perot interferometers

Back to Top