7 March 2003 A comparison of open versus closed loop flexure compensation systems for two Keck optical imaging spectrographs: ESI and DEIMOS
Author Affiliations +
Abstract
Two recent Keck optical imaging spectrographs have been designed with active flexure compensation systems (FCS). These two instruments utilize different methods for implementing flexure compensation. The Echellette Spectrograph and Imager (ESI), commissioned at the Cassegrain focus of the Keck II Telescope in late 1999, employs an open-loop control strategy. It utilizes a mathematical model of gravitationally-induced flexure to periodically compute flexure corrections as a function of telescope position. Those corrections are then automatically applied to a tip/tilt collimator to stabilize the image on the detector. The DEep Imaging Multi-Object Spectrograph (DEIMOS), commissioned at the Nasmyth focus of Keck II in June 2002, implements a closed-loop control strategy. It utilizes a set of fiber-fed FCS light sources at the ends of the slitmask to produce a corresponding set of spots on a pair of FCS CCD detectors located on either side of the science CCD mosaic. During science exposures, the FCS detectors are read out several times per minute to measure any translational motion of the FCS spot images. Correction signals derived from these FCS images are used to drive active optical mechanisms which steer the spots back to their nominal positions, thus stabilizing the FCS spot images as well as those on the science mosaic. We compare the design, calibration, and operation of these two systems on the telescope. Long-term performance results will be provided for the ESI FCS, and preliminary results will be provided for the DEIMOS FCS.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert I. Kibrick, Sandra M. Faber, Andrew C. Phillips, Molly McVeigh, David J. Cowley, Matthew V. Radovan, David Kirk Gilmore, Christopher A.F. Wright, Dean Tucker, De Clarke, and Steven L. Allen "A comparison of open versus closed loop flexure compensation systems for two Keck optical imaging spectrographs: ESI and DEIMOS", Proc. SPIE 4841, Instrument Design and Performance for Optical/Infrared Ground-based Telescopes, (7 March 2003); https://doi.org/10.1117/12.461602
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fluorescence correlation spectroscopy

Charge-coupled devices

Spectrographs

Mirrors

Sensors

Calibration

Telescopes

RELATED CONTENT

The 4MOST facility control software
Proceedings of SPIE (July 26 2016)
Progress on the WHT natural guide star AO system (NAOMI)
Proceedings of SPIE (October 17 1997)
Experimental system of segmented-mirror active optics
Proceedings of SPIE (July 20 2000)
bHROS installation and system performance
Proceedings of SPIE (September 30 2004)

Back to Top