Paper
4 May 2004 Only stereo information improves performance in surgical tasks
Joerg W. Huber, Neil S. Stringer, Ian R. L. Davies, David Field
Author Affiliations +
Abstract
Laboratory based research has shown that the use of stereoscopic displays and observer-produced motion parallax in telepresence systems can each improve operators' performance beyond that achieved using conventional 2-D displays. In applied contexts such as minimal access surgery (MAS) tasks are more complex and a range of sources of depth information is available. We therefore decided to examine the benefits of stereoscopic displays and observer-produced motion parallax under more realistic conditions. The 'pick and place' task was taken from surgical performance studies. It involved picking up small irregular spheres from one place and dropping them through apertures in another. The task was performed under seven different viewing conditions: (1) baseline (monocular), (2) biocular, (3) stereoscopic, (4) free motion parallax, (5) instructed motion parallax, (6) augmented motion parallax and (7) stereo and motion parallax. Each subject did a baseline condition (monocular viewing) followed by one of the seven experimental conditions, followed by a final block of the baseline condition (n = 7 conditions x 10 subjects). Only stereoscopic viewing (conditions 3 and 7) leads to better performance. The provision of motion parallax adds nothing to performance. It may even reduce the effectiveness of stereoscopic viewing. The evidence converges on the fact that binocular viewing confers a considerable performance advantage, while providing motion parallax information, to novice operators at least, is not beneficial.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joerg W. Huber, Neil S. Stringer, Ian R. L. Davies, and David Field "Only stereo information improves performance in surgical tasks", Proc. SPIE 5372, Medical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment, (4 May 2004); https://doi.org/10.1117/12.544718
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Surgery

Head

Cameras

Eye

Cones

Stereoscopic displays

3D vision

RELATED CONTENT

Virtual Window Viewing Geometry
Proceedings of SPIE (January 05 1989)
The camera convergence problem revisited
Proceedings of SPIE (May 21 2004)
Teleoperator performance with virtual window display
Proceedings of SPIE (August 01 1991)
Visual-Motor Realism In 3D Teleoperator Display Systems
Proceedings of SPIE (June 16 1987)
Design of monocular multiview stereoscopic 3D display
Proceedings of SPIE (June 04 2001)

Back to Top