Paper
17 March 2005 Irradiation of orderly multiline spectra from linear plasma formed by vacuum discharge capillary
Eiichi Sato, Yasuomi Hayasi, Rudolf Germer, Hidenori Ojima, Kazuyoshi Takayama, Hideaki Ido
Author Affiliations +
Proceedings Volume 5580, 26th International Congress on High-Speed Photography and Photonics; (2005) https://doi.org/10.1117/12.568980
Event: 26th International Congress on High-Speed Photography and Photonics, 2004, Alexandria, Virginia, United States
Abstract
The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments are primarily performed in order to generate intense soft x rays. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbomolecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -11.5 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 μm aluminum filter were less than 30 μs. In the spectrum measurement, we observed orderly multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. The line number decreased with corresponding decreases in the capillary length.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Yasuomi Hayasi, Rudolf Germer, Hidenori Ojima, Kazuyoshi Takayama, and Hideaki Ido "Irradiation of orderly multiline spectra from linear plasma formed by vacuum discharge capillary", Proc. SPIE 5580, 26th International Congress on High-Speed Photography and Photonics, (17 March 2005); https://doi.org/10.1117/12.568980
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Capillaries

X-rays

Aluminum

Plasma

Electrodes

Power supplies

Pulse generators

RELATED CONTENT

Flash vacuum-ultraviolet generator having a mercury-anode tube
Proceedings of SPIE (September 01 1995)
Flash water-window x-ray generator WFX-98
Proceedings of SPIE (June 22 1999)
Water window flash x ray production from linear plasma x...
Proceedings of SPIE (December 18 2000)
High-speed soft x-ray techniques
Proceedings of SPIE (May 28 1997)

Back to Top