29 April 2005 Semi-automatic border detection method for left ventricular volume estimation in 4D ultrasound data
Marijn van Stralen, Johan G. Bosch, Marco M. Voormolen, Gerard van Burken, Boudewijn J. Krenning, Robert Jan M. van Geuns M.D., Emmanuelle Angelie, Rob J. van der Geest, Charles T. Lancee, Nico de Jong, Johan Hans C. Reiber
Author Affiliations +
Abstract
We propose a semi-automatic endocardial border detection method for LV volume estimation in 3D time series of cardiac ultrasound data. It is based on pattern matching and dynamic programming techniques and operates on 2D slices of the 4D data requiring minimal user-interaction. We evaluated on data acquired with the Fast Rotating Ultrasound (FRU) transducer: a linear phased array transducer rotated at high speed around its image axis, generating high quality 2D images of the heart. We automatically select a subset of 2D images at typically 10 rotation angles and 16 cardiac phases. From four manually drawn contours a 4D shape model and a 4D edge pattern model is derived. For the selected images, contour shape and edge patterns are estimated using the models. Pattern matching and dynamic programming is applied to detect the contours automatically. The method allows easy corrections in the detected 2D contours, to iteratively achieve more accurate models and improved detections. An evaluation of this method on FRU data against MRI was done for full cycle LV volumes on 10 patients. Good correlations were found against MRI volumes [r=0.94, y=0.72x + 30.3, difference of 9.6 +/- 17.4 ml (Av +/- SD)] and a low interobserver variability for US (r=0.94, y=1.11x - 16.8, difference of 1.4 +/- 14.2 ml). On average only 2.8 corrections per patient were needed (in a total of 160 images). Although the method shows good correlations with MRI without corrections, applying these corrections can make significant improvements.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marijn van Stralen, Johan G. Bosch, Marco M. Voormolen, Gerard van Burken, Boudewijn J. Krenning, Robert Jan M. van Geuns M.D., Emmanuelle Angelie, Rob J. van der Geest, Charles T. Lancee, Nico de Jong, and Johan Hans C. Reiber "Semi-automatic border detection method for left ventricular volume estimation in 4D ultrasound data", Proc. SPIE 5747, Medical Imaging 2005: Image Processing, (29 April 2005); https://doi.org/10.1117/12.596876
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic resonance imaging

Ultrasonography

3D modeling

Transducers

Computer programming

Image segmentation

3D image processing

Back to Top