28 March 2007 A contrast-detail comparison of computed mammotomography and digital mammography
Author Affiliations +
Abstract
We use a contrast-detail observer study to compare performance of a novel 3D computed mammotomography (CmT) system with a commercially developed full-field digital mammography (FFDM) system. A contrast-detail phantom comprised of uniform acrylic spheres of various diameters was developed and placed in a variety of mediums including uniform water (simulating low contrast lesions within a uniform background), water and acrylic yarn (simulating low contrast lesions with over/under-lying structure), oil only (simulating higher contrast lesions in a uniform background), and oil and acrylic yarn (simulating higher contrast lesions with over/under-lying structure). For CmT, the phantom was placed in a 14.6 cm diameter uncompressed breast phantom and projections acquired using a simple circular orbit, W-target tube, 60 kVp tube potential, 0.05 cm Ce filtration, 4 mAs per projection, and a CsI(Tl) digital x-ray detector. Reconstructions used an iterative OSTR algorithm. For FFDM, the phantom was placed in a 5.3-cm-thick compressed breast phantom. Single CC-view mammograms were acquired using a clinical W-target tube with 50 um Rh filtration, 28 kVp, photo-timed mAs per our clinical mammography operation, and a Selenium-based flat-panel detector (Mammomat Novation, Siemens). Six observers evaluated the images in terms of the number of detectable spheres. FFDM performed significantly better for the low contrast lesions in uniform water background (p<0.05). However, CmT performed significantly better for all other cases (p<0.05). Results indicate that CmT shows significant advantage in soft tissue detection over FFDM in otherwise low contrast dense breasts.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Randolph L. McKinley III, Martin P. Tornai, Carey E. Floyd, and Ehsan Samei "A contrast-detail comparison of computed mammotomography and digital mammography", Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 65101D (28 March 2007); https://doi.org/10.1117/12.713032
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical spheres

Breast

Mammography

Digital mammography

Sensors

X-ray detectors

Computing systems

Back to Top