Paper
26 February 2008 Non-homogeneous ICD optimization for targeted reconstruction of volumetric CT
Author Affiliations +
Proceedings Volume 6814, Computational Imaging VI; 681404 (2008) https://doi.org/10.1117/12.777140
Event: Electronic Imaging, 2008, San Jose, California, United States
Abstract
Medical imaging typically requires the reconstruction of a limited region of interest (ROI) to obtain a high resolution image of the anatomy of interest. Although targeted reconstruction is straightforward for analytical reconstruction methods, it is more complicated for statistical iterative techniques, which must reconstruct all objects in the field of view (FOV) to account for all sources of attenuation along the ray paths from x-ray source to detector. A brute force approach would require the reconstruction of the full field of view in high-resolution, but with prohibitive computational cost. In this paper, we propose a multi-resolution approach to accelerate targeted iterative reconstruction using the non-homogeneous ICD (NH-ICD) algorithm. NH-ICD aims at speeding up convergence of the coordinate descent algorithm by selecting preferentially those voxels most in need of updating. To further optimize ROI reconstruction, we use a multi-resolution approach which combines three separate improvements. First, we introduce the modified weighted NH-ICD algorithm, which weights the pixel selection criteria according to the position of the voxel relative to the ROI to speed up convergence within the ROI. Second, we propose a simple correction to the error sinogram to correct for inconsistencies between resolutions when the forward model is not scale invariant. Finally, we leverage the flexibility of the ICD algorithm to add selected edge pixels outside the ROI to the ROI reconstruction in order to minimize transition artifacts at the ROI boundary. Experiments on clinical data illustrate how each component of the method improves convergence speed and image quality.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhou Yu, Jean-Baptiste Thibault, Charles A. Bouman, Ken D. Sauer, and Jiang Hsieh "Non-homogeneous ICD optimization for targeted reconstruction of volumetric CT", Proc. SPIE 6814, Computational Imaging VI, 681404 (26 February 2008); https://doi.org/10.1117/12.777140
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Image quality

Detection and tracking algorithms

Image resolution

Medical imaging

CT reconstruction

Quality measurement

Back to Top