Paper
26 March 2008 Image intensity standardization in 3D rotational angiography and its application to vascular segmentation
Author Affiliations +
Abstract
Knowledge-based vascular segmentation methods typically rely on a pre-built training set of segmented images, which is used to estimate the probability of each voxel to belong to a particular tissue. In 3D Rotational Angiography (3DRA) the same tissue can correspond to different intensity ranges depending on the imaging device, settings and contrast injection protocol. As a result, pre-built training sets do not apply to all images and the best segmentation results are often obtained when the training set is built specifically for each individual image. We present an Image Intensity Standardization (IIS) method designed to ensure a correspondence between specific tissues and intensity ranges common to every image that undergoes the standardization process. The method applies a piecewise linear transformation to the image that aligns the intensity histogram to the histogram taken as reference. The reference histogram has been selected from a high quality image not containing artificial objects such as coils or stents. This is a pre-processing step that allows employing a training set built on a limited number of standardized images for the segmentation of standardized images which were not part of the training set. The effectiveness of the presented IIS technique in combination with a well-validated knowledge-based vasculature segmentation method is quantified on a variety of 3DRA images depicting cerebral arteries and intracranial aneurysms. The proposed IIS method offers a solution to the standardization of tissue classes in routine medical images and effectively improves automation and usability of knowledge-based vascular segmentation algorithms.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hrvoje Bogunović, Alessandro G. Radaelli, Mathieu De Craene, David Delgado, and Alejandro F. Frangi "Image intensity standardization in 3D rotational angiography and its application to vascular segmentation", Proc. SPIE 6914, Medical Imaging 2008: Image Processing, 691419 (26 March 2008); https://doi.org/10.1117/12.770564
Lens.org Logo
CITATIONS
Cited by 15 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image segmentation

Image processing

Tissues

Medical imaging

3D imaging standards

Image registration

Brain

RELATED CONTENT


Back to Top