Paper
6 March 2008 SPECT image system optimization using ideal observer for detection and localization
Author Affiliations +
Abstract
We consider the problem of optimizing collimator characteristics for a simple emission tomographic imaging system. We use the performance of two different ideal observers to carry out the optimization. The first ideal observer applies to signal detection when signal location is unknown and background is variable, and the second ideal observer (one proposed previously by our group) to the more realistic task of signal detection and localization with signal location unknown and background variable. The two observers operate on sinogram data to deliver scalar figures of merit AROC and ALROC, respectively. We considered three different collimators that span a range of efficiency-resolution tradeoffs. Our central question is this: For optimizing the collimator in an emission tomographic system, does adding a localization requirement to a detection task yield an efficiency-resolution tradeoff that differs from that for the detection-only task? Our simulations with a simple SPECT imaging system show that as the localization requirement becomes more stringent, the optimal collimator shifts from a low-resolution, high efficiency version toward higher resolution, lower efficiency version. We had previously observed such behavior for a planar pinhole imaging system. In our simulations, we used a simplified model of tomographic imaging and a simple model for object background variability. This allowed us to avoid the severe computational complexity associated with ideal-observer performance calculations. Thus the more realistic task (i.e. localization included) resulted for this case in a different optimal collimator.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lili Zhou and Gene Gindi "SPECT image system optimization using ideal observer for detection and localization", Proc. SPIE 6917, Medical Imaging 2008: Image Perception, Observer Performance, and Technology Assessment, 69171D (6 March 2008); https://doi.org/10.1117/12.770676
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Collimators

Imaging systems

Tolerancing

Signal detection

Single photon emission computed tomography

Signal attenuation

Tomography

Back to Top