Paper
16 September 2008 Quantitative investigation of phase retrieval from x-ray phase-contrast tomographic images
H. O. Moser, K. Banas, A. Chen, T. Vo Nghia, L. K. Jian, S. M. P. Kalaiselvi, G. Liu, S. M. Maniam, P. D. Gu, S. W. Wilkins, T. E. Gureyev, S. C. Mayo, M. Cholewa, Z. J. Li
Author Affiliations +
Abstract
X-ray phase-contrast tomographic microimaging is a powerful tool to reveal the internal structure of opaque soft-matter objects that are not easily seen in standard absorption contrast. In such low Z materials, the phase shift of X-rays transmitted can be important as compared to the absorption. An easy experimental set up that exploits refractive contrast formation can deliver images that are providing detailed structural information. Applications are abundant in fields including polymer science and engineering, biology, biomedical engineering, life sciences, zoology, water treatment and filtration, membrane science, and micro/nanomanufacturing. However, available software for absorptive contrast tomography cannot be simply used for structure retrieval as the contrast forming effect is different. In response, CSIRO has developed a reconstruction code for phase-contrast imaging. Here, we present a quantitative comparison of a micro phantom manufactured at SSLS with the object reconstructed by the code using X-ray images taken at SSLS. The phantom is a 500 μm thick 800 μm diameter cylindrical disk of SU-8 resist having various eccentric cylindrical bores with diameters ranging from 350 μm to 40 μm. Comparison of these parameters that are well known from design and post-manufacturing measurements with reconstructed ones gives encouraging results.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
H. O. Moser, K. Banas, A. Chen, T. Vo Nghia, L. K. Jian, S. M. P. Kalaiselvi, G. Liu, S. M. Maniam, P. D. Gu, S. W. Wilkins, T. E. Gureyev, S. C. Mayo, M. Cholewa, and Z. J. Li "Quantitative investigation of phase retrieval from x-ray phase-contrast tomographic images", Proc. SPIE 7078, Developments in X-Ray Tomography VI, 707814 (16 September 2008); https://doi.org/10.1117/12.794497
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Tomography

X-ray imaging

Solid state lighting

Absorption

Refractive index

Phase retrieval

Back to Top