Paper
23 March 2010 Reliability study of reconstruction methods in tomosynthesis imaging of various geometrical objects
Karthik Kanaka, Ravi K. Samala, Jianying Zhang, Wei Qian
Author Affiliations +
Abstract
The primary objective of this paper is to illustrate the applicability of reconstruction methods to objects of various geometrical shapes. Reconstruction methods are compared by evaluating the efficiency in reconstruction of individual geometric shapes. Signal difference noise ratio, artifact spread function; object extension and artifact extension are taken into consideration to determine the efficiency of the reconstruction methods. The reliability of reconstruction methods is compared qualitatively as well as quantitatively by graphically plotting the cumulative average of individual parameters against corresponding reconstruction methods. All the four parameters are found to be in good agreement with one another. Seven different filters namely Shift add filter, filtered back projection, enhanced shift add filter, enhanced filtered back projection, enhanced 2 shift add filter, enhanced 2 filtered back projection filter, enhanced 3 filtered back projection filter are compared in this paper for the quality of reconstruction and their reliability. Of all the methods, enhanced 3 filtered back projection proved to be the best one. Filtered back projection filter is found to have a clear edge over the shift add filter in viewing cylindrical as well as spherical objects. Besides, shift and add filter fails to trace minute spherical objects. Also, the histograms of average image contrast and average number of slices of both cylinder and the sphere clearly drive home the point. The more the number of slices, the greater is the image resolution. Likewise, the more the signal difference noise ratio, the better the image quality.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Karthik Kanaka, Ravi K. Samala, Jianying Zhang, and Wei Qian "Reliability study of reconstruction methods in tomosynthesis imaging of various geometrical objects", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 762246 (23 March 2010); https://doi.org/10.1117/12.844399
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Signal to noise ratio

Interference (communication)

Image filtering

Optical spheres

Reliability

Spherical lenses

Mammography

RELATED CONTENT


Back to Top