Paper
9 March 2010 CT liver volumetry using geodesic active contour segmentation with a level-set algorithm
Kenji Suzuki, Mark L. Epstein, Ryan Kohlbrenner, Ademola Obajuluwa, Jianwu Xu, Masatoshi Hori M.D., Richard Baron M.D.
Author Affiliations +
Abstract
Automatic liver segmentation on CT images is challenging because the liver often abuts other organs of a similar density. Our purpose was to develop an accurate automated liver segmentation scheme for measuring liver volumes. We developed an automated volumetry scheme for the liver in CT based on a 5 step schema. First, an anisotropic smoothing filter was applied to portal-venous phase CT images to remove noise while preserving the liver structure, followed by an edge enhancer to enhance the liver boundary. By using the boundary-enhanced image as a speed function, a fastmarching algorithm generated an initial surface that roughly estimated the liver shape. A geodesic-active-contour segmentation algorithm coupled with level-set contour-evolution refined the initial surface so as to more precisely fit the liver boundary. The liver volume was calculated based on the refined liver surface. Hepatic CT scans of eighteen prospective liver donors were obtained under a liver transplant protocol with a multi-detector CT system. Automated liver volumes obtained were compared with those manually traced by a radiologist, used as "gold standard." The mean liver volume obtained with our scheme was 1,520 cc, whereas the mean manual volume was 1,486 cc, with the mean absolute difference of 104 cc (7.0%). CT liver volumetrics based on an automated scheme agreed excellently with "goldstandard" manual volumetrics (intra-class correlation coefficient was 0.95) with no statistically significant difference (p(F≤f)=0.32), and required substantially less completion time. Our automated scheme provides an efficient and accurate way of measuring liver volumes.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kenji Suzuki, Mark L. Epstein, Ryan Kohlbrenner, Ademola Obajuluwa, Jianwu Xu, Masatoshi Hori M.D., and Richard Baron M.D. "CT liver volumetry using geodesic active contour segmentation with a level-set algorithm", Proc. SPIE 7624, Medical Imaging 2010: Computer-Aided Diagnosis, 76240R (9 March 2010); https://doi.org/10.1117/12.843950
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Liver

Computed tomography

Image segmentation

Anisotropic filtering

Image processing algorithms and systems

Image filtering

Gold

Back to Top