Paper
1 April 2010 Dimensional metrology with sub-nanometer uncertainty: unique role of AFM as the reference
Author Affiliations +
Abstract
The 2007 edition of ITRS has introduced a new metric for metrology quality assessment - measurement uncertainty (MU). The new metric has precision as one of many uncertainty components. Additional significant components are tool matching, sampling uncertainty and sample-to-sample bias variation. Sample dependent bias variation and, therefore, MU can be measured accurately only if a reference metrology (RM) is employed. RM is a must for achieving and verifying required today sub-nanometer MU of critical dimension (CD) metrology. To insure long-term performance of in-line metrology and reliable process control a simple but efficient way is suggested - employment of in-line RM system. SI-traceable CD AFM with sub-nanometer MU is a proper RM tool for the task.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vladimir A. Ukraintsev and Johann Foucher "Dimensional metrology with sub-nanometer uncertainty: unique role of AFM as the reference", Proc. SPIE 7638, Metrology, Inspection, and Process Control for Microlithography XXIV, 76381C (1 April 2010); https://doi.org/10.1117/12.846870