Paper
27 August 2010 Feasibility study of CCD-based gamma camera
Hakjae Lee, Young-Jun Jeong, Joochul Yoon, Jungwon Kang, Sangjoon Lee, Hyungsup Shin, Kisung Lee
Author Affiliations +
Abstract
Conventional gamma cameras which uses photomultiplier tubes(PMT) is very heavy, bulky, and expensive. In addition, its spatial resolution is low because of geometrical limitation of PMTs. This low resolution and large size is not efficient for the small animal imaging system which is useful in preclinical imaging application. We have developed a small size but high spatial resolution gamma ray detector, based on charge-coupled device(CCD) which is useful to develop a prototype model of small animal gamma camera. Recently the sensitivity of CCD was improved and the peltier cooling system helped to minimize the dark currents of CCD significantly. The enhanced sensitivity and high intrinsic resolution of CCD enabled researchers to develop the small size gamma camera with low cost. In this study we used peltier cooled CCD sensor which has about 70% of quantum efficiency at 650nm wave length. CsI(Tl) scintillator was also used to convert the gamma ray to visible lights. These light photons from the scintillator have been collected to the CCD surface by Nikorr macro lens to enhance the collection efficiency. The experimental results showed that the proposed CCD-based detection system is feasible for gamma ray detection.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hakjae Lee, Young-Jun Jeong, Joochul Yoon, Jungwon Kang, Sangjoon Lee, Hyungsup Shin, and Kisung Lee "Feasibility study of CCD-based gamma camera", Proc. SPIE 7805, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XII, 780518 (27 August 2010); https://doi.org/10.1117/12.862717
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Charge-coupled devices

Scintillators

Sensors

CCD cameras

Spatial resolution

Gamma radiation

RELATED CONTENT

The progress of sub-pixel imaging methods
Proceedings of SPIE (February 21 2014)
Design of a CCD camera prototype for the Earth 2.0...
Proceedings of SPIE (August 27 2022)
The WIYN One Degree Imager: an update
Proceedings of SPIE (July 11 2008)
The Modular Charge-Coupled Device (CCD) Camera
Proceedings of SPIE (December 12 1979)
Scanned Projection Radiography With A Slot Beam
Proceedings of SPIE (June 27 1988)

Back to Top