Paper
13 September 2012 Design and test results of the calibration unit for the MOAO demonstrator RAVEN
Author Affiliations +
Abstract
INO has designed, assembled and tested the Raven Multi-Object Adaptive Optics demonstrator calibration unit. This sub-system consists in a telescope simulator that will allow aligning Raven's components during its integration, testing its Adaptive Optics performances in the laboratory and at the telescope, and calibrating the Adaptive Optics system by building the interaction matrix and measuring the non-common path aberrations. The system is presented with the challenges that needed to be overcome during the design and integration phases. The system test results are also presented and compared to the model predictions.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
J.-F. Lavigne, F. Lamontagne, G. Anctil, M. Wang, M. Tremblay, O. Lardière, R. Nash, D. Andersen, M. Savard, P. Côté, C. H. Bradley, and F. Châteauneuf "Design and test results of the calibration unit for the MOAO demonstrator RAVEN", Proc. SPIE 8447, Adaptive Optics Systems III, 844754 (13 September 2012); https://doi.org/10.1117/12.925489
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Adaptive optics

Calibration

Telescopes

Tolerancing

Zemax

Diffraction

Stars

RELATED CONTENT

Solving the NFIRAOS calibration puzzle
Proceedings of SPIE (July 26 2016)
A review of high contrast imaging modes for METIS
Proceedings of SPIE (July 16 2018)
Study of the impact of E ELT and MICADO distortion...
Proceedings of SPIE (August 04 2016)

Back to Top