Paper
26 February 2013 Targeted hyperthermia in prostate with an MR-guided endorectal ultrasound phased array: patient specific modeling and preliminary experiments
Vasant A. Salgaonkar, Punit Prakash, Juan Plata, Andrew Holbrook, Viola Rieke, John Kurhanewicz, I-C. Hsu, Chris J. Diederich
Author Affiliations +
Abstract
Feasibility of hyperthermia delivery to the prostate with a commercially available MR-guided endorectal ultrasound (ERUS) phased array ablation system (ExAblate 2100, Insightec, LTD) was assessed through computer simulations and ex vivo experiments. The simulations included a 3D FEM-based biothermal model, and acoustic field calculations for the ExAblate phased array (2.3 MHz, 2.3x4.0 cm2) using the rectangular radiator method. Array beamforming strategies were investigated to deliver 30-min hyperthermia (<41 °C) to focal regions of prostate cancer, identified from MR images in representative patient cases. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. T<41 °C was calculated in 14-19 cm3 for sonications with planar or diverging beam patterns at 0.9-1.2 W/cm2, and in 3-10 cm3 for curvilinear (cylindrical) or multifocus beam patterns at 1.5-3.3 W/cm2, potentially useful for treating focal disease in a single posterior quadrant. Preliminary experiments included beamformed sonications in tissue mimicking phantom material under MRI-based temperature monitoring at 3T (GRE TE=7.0 ms, TR=15 ms, BW=10.5 kHz, FOV=15 cm, matrix 128x128, FA=40°). MR-temperature rises of 2-6 °C were induced in a phantom with the ExAblate array, consistent with calculated values and lower power settings (~0.86 W/cm2, 3 min.). Conformable hyperthermia may be delivered by tailoring power deposition along the array length and angular expanse. MRgERUS HIFU systems can be controlled for continuous hyperthermia in prostate to augment radiotherapy and drug delivery. [FUS Foundation, NIH R01 122276, 111981].
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vasant A. Salgaonkar, Punit Prakash, Juan Plata, Andrew Holbrook, Viola Rieke, John Kurhanewicz, I-C. Hsu, and Chris J. Diederich "Targeted hyperthermia in prostate with an MR-guided endorectal ultrasound phased array: patient specific modeling and preliminary experiments", Proc. SPIE 8584, Energy-based Treatment of Tissue and Assessment VII, 85840U (26 February 2013); https://doi.org/10.1117/12.2004609
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Prostate

Phased arrays

Acoustics

Tissues

Tumors

Ultrasonography

Magnetic resonance imaging

Back to Top